<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>12\/24 KV &#8211; JYTOP Cable</title>
	<atom:link href="https://italian.baoliyy.com/tag/12-24-kv/feed/" rel="self" type="application/rss+xml" />
	<link>https://italian.baoliyy.com</link>
	<description>Fabbricazione AAC / AAAC / ACSR CONDUCTOR, cavo XLPE, cavo in PVC, cavo ABC, cavo di alimentazione</description>
	<lastBuildDate>Mon, 16 Sep 2019 07:08:10 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>12/24 KV PE Jacket NFC 33226 Standard Service Drop Cable</title>
		<link>https://italian.baoliyy.com/12-24-kv-pe-jacket-nfc-33226-standard-service-drop-cable/</link>
				<comments>https://italian.baoliyy.com/12-24-kv-pe-jacket-nfc-33226-standard-service-drop-cable/#respond</comments>
				<pubDate>Mon, 16 Sep 2019 07:08:10 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[yifang]]></category>
		<category><![CDATA[12\/24 KV]]></category>
		<category><![CDATA[NFC 33226]]></category>
		<category><![CDATA[service drop cable]]></category>

		<guid isPermaLink="false">https://italian.baoliyy.com/12-24-kv-pe-jacket-nfc-33226-standard-service-drop-cable/</guid>
				<description><![CDATA[12/24 KV Media Tensione Cavo Sotterraneo con NFC 33226 Standard &#160; Descrizione del prodotto &#160; STANDARD nazionale:NF C 33-226 DESCRIZIONE UTILIZZO NF C 33-226 cavi sono la nuova generazione di cavi per la pubblica rete di distribuzione elettrica 12/20 kV. essi sono AD8 (pressione dell&#039;acqua &#60; 0,2 bar), AF2 e AN3 conformi alle norme di [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>12/24 KV Media Tensione Cavo Sotterraneo con NFC 33226 Standard</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-j3um0" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-j3um0" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Descrizione del prodotto</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<div style="margin-bottom: 10.0px;color: #333333;font-family: arial , helvetica , sans-serif;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: 20.0px;background-color: #f3f3f3">
<h3 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em">STANDARD</h3>
<p><strong>nazionale:</strong>NF C 33-226</div>
<h3 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;color: #333333;font-family: arial , helvetica , sans-serif;font-style: normal;line-height: 20.0px;background-color: #f3f3f3">DESCRIZIONE</h3>
<p>UTILIZZO</p>
<div style="float: left;margin-right: 20.0px;width: 466.0px;color: #333333;font-family: arial , helvetica , sans-serif;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: 20.0px;background-color: #f3f3f3">
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">NF C 33-226 cavi sono la nuova generazione di cavi per la pubblica rete di distribuzione elettrica 12/20 kV. essi sono AD8 (pressione dell&#039;acqua &lt; 0,2 bar), AF2 e AN3 conformi alle norme di NF C 13-200 standard. guaina &egrave; anti-termite resistente.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">&nbsp;</p>
<h2 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;font-weight: bold;color: #333333;line-height: 1.3">DISEGNO</h2>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">il cavo &egrave; realizzato in 1 o 3 nuclei ricompattato.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">&nbsp;</p>
<h2 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;font-weight: bold;color: #333333;line-height: 1.3">CONDIZIONE di POSA</h2>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">sepoltura profondit&agrave;: 0.80 m</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">terreno termica resistivit&agrave;: 1.2 &deg; K m/W</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">&nbsp;</p>
<h2 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;font-weight: bold;color: #333333;line-height: 1.3">CARACTERISTICS ELETTRICO</h2>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">&nbsp;</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">calcolata dal IEC 60949, ammissibile corrente di corto circuito &egrave; applicabile per il conduttore durante 1 s.</p>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">&nbsp;</p>
<h2 style="margin: 0.0px;padding: 0.0px;font-size: 1.16667em;font-weight: bold;color: #333333;line-height: 1.3">OPZIONI</h2>
<p style="margin: 1.0em 0.0px;padding: 0.5em 0.0px;line-height: 1.66667em">NF C 33-226 cavi possono essere fabbricati con le seguenti opzioni:</p>
<ul>
<li style="margin: 0.0px;padding: 0.0px">conduttore di rame</li>
<li style="margin: 0.0px;padding: 0.0px">altra tensione</li>
<li style="margin: 0.0px;padding: 0.0px">altra sezione</li>
<li style="margin: 0.0px;padding: 0.0px">messa a terra conduttore</li>
<li style="margin: 0.0px;padding: 0.0px">pi&ugrave; spessa di alluminio schermo</li>
<li style="margin: 0.0px;padding: 0.0px">grappolo</li>
<li style="margin: 0.0px;padding: 0.0px"><strong>rinforzato seppellire resistenza (EDR)</strong>&egrave; garantita con una protezione di polietilene estruso.</li>
<li style="margin: 0.0px;padding: 0.0px">
<h2 style="margin: 0.0px;padding: 0.0px 20.0px;font-size: 1.66667em;font-weight: normal;color: #333333;line-height: 1.3;font-family: arial , helvetica , sans-serif;font-style: normal">caratteristiche</h2>
<div style="margin-top: 10.0px;padding: 20.0px 20.0px 12.0px;color: #333333;font-family: arial , helvetica , sans-serif;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: 20.0px;background: 0.0% 0.0% no-repeat transparent">
<div style="overflow:auto"><table style="border-collapse: collapse;width: 651.0px;height: 439.0px">
<tbody>
<tr style="height: 19.0px">
<th style="padding: 1.4em 20.0px 0.8em;font-size: 1.16667em;font-weight: bold;text-align: left;width: 607.778px;height: 19.0px">COSTRUZIONE CARATTERISTICHE</th>
</tr>
<tr style="height: 18.0px;background-color: #dddddd">
<td style="width: 300.0px;padding: 0.3em 20.0px;height: 18.0px">conduttore flessibilit&agrave;</td>
<td style="width: 266.667px;padding: 0.3em 20.0px;height: 18.0px">Stranded classe 2</td>
</tr>
<tr style="height: 19.0px">
<th style="padding: 1.4em 20.0px 0.8em;font-size: 1.16667em;font-weight: bold;text-align: left;width: 607.778px;height: 19.0px">CARATTERISTICHE DIMENSIONALI</th>
</tr>
<tr style="height: 18.0px;background-color: #dddddd">
<td style="width: 300.0px;padding: 0.3em 20.0px;height: 18.0px">spessore schermo</td>
<td style="width: 266.667px;padding: 0.3em 20.0px;height: 18.0px">150 &amp; micro; m</td>
</tr>
<tr style="height: 19.0px">
<th style="padding: 1.4em 20.0px 0.8em;font-size: 1.16667em;font-weight: bold;text-align: left;width: 607.778px;height: 19.0px">CARATTERISTICHE ELETTRICHE</th>
</tr>
<tr style="height: 18.0px;background-color: #dddddd">
<td style="width: 300.0px;padding: 0.3em 20.0px;height: 18.0px">Tensione nominale Uo/U (Um)</td>
<td style="width: 266.667px;padding: 0.3em 20.0px;height: 18.0px">12/20 (24) kV</td>
</tr>
<tr style="height: 19.0px">
<th style="padding: 1.4em 20.0px 0.8em;font-size: 1.16667em;font-weight: bold;text-align: left;width: 607.778px;height: 19.0px">CARATTERISTICHE MECCANICHE</th>
</tr>
<tr style="height: 18.0px;background-color: #dddddd">
<td style="width: 300.0px;padding: 0.3em 20.0px;height: 18.0px">resistenza agli impatti meccanici</td>
<td style="width: 266.667px;padding: 0.3em 20.0px;height: 18.0px">AG4</td>
</tr>
<tr style="height: 19.0px">
<th style="padding: 1.4em 20.0px 0.8em;font-size: 1.16667em;font-weight: bold;text-align: left;width: 607.778px;height: 19.0px">CARATTERISTICHE di UTILIZZO</th>
</tr>
<tr style="height: 18.0px;background-color: #dddddd">
<td style="width: 300.0px;padding: 0.3em 20.0px;height: 18.0px">ambiente temperatura di installazione, gamma</td>
<td style="width: 266.667px;padding: 0.3em 20.0px;height: 18.0px">-10 .. 50 &deg; C</td>
</tr>
<tr style="height: 18.0px">
<td style="width: 300.0px;padding: 0.3em 20.0px;height: 18.0px">resistenza agli agenti atmosferici</td>
<td style="width: 266.667px;padding: 0.3em 20.0px;height: 18.0px">AN3/AF2</td>
</tr>
<tr style="height: 18.0px;background-color: #dddddd">
<td style="width: 300.0px;padding: 0.3em 20.0px;height: 18.0px">ritardante di fiamma</td>
<td style="width: 266.667px;padding: 0.3em 20.0px;height: 18.0px">C2, NF C 32-070</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</li>
</ul>
</div>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-06g05" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-06g05" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">imballaggio e Spedizione</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-jjrr2" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-jjrr2" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Drum Imballaggio</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-a8hgs" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-a8hgs" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">certificazioni</span></div>
<div style="padding: 10.0px 0">
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-xtayj" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-xtayj" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Contattarci</span></div>
<div style="padding: 10.0px 0">
<p><span style="font-size: 14.0px">benvenuto alla nostra fabbrica, speriamo di ottenere in contatto con voi.</span></p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://italian.baoliyy.com/12-24-kv-pe-jacket-nfc-33226-standard-service-drop-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
