<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>3&#215;50 XLPE cable aluminum \/ copper insulation &#8211; JYTOP Cable</title>
	<atom:link href="https://italian.baoliyy.com/tag/3x50-xlpe-cable-aluminum-copper-insulation/feed/" rel="self" type="application/rss+xml" />
	<link>https://italian.baoliyy.com</link>
	<description>Fabbricazione AAC / AAAC / ACSR CONDUCTOR, cavo XLPE, cavo in PVC, cavo ABC, cavo di alimentazione</description>
	<lastBuildDate>Wed, 11 Sep 2019 02:05:20 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.26</generator>
	<item>
		<title>IEC standard XLPE insulated copper cable 3x95sqmm</title>
		<link>https://italian.baoliyy.com/iec-standard-xlpe-insulated-copper-cable-3x95sqmm/</link>
				<comments>https://italian.baoliyy.com/iec-standard-xlpe-insulated-copper-cable-3x95sqmm/#respond</comments>
				<pubDate>Wed, 11 Sep 2019 02:05:20 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[11KV XLPE insulated STA armored power cable]]></category>
		<category><![CDATA[1KV underground XLPE cable 4x25mm]]></category>
		<category><![CDATA[3x50 XLPE cable aluminum \/ copper insulation]]></category>

		<guid isPermaLink="false">https://italian.baoliyy.com/iec-standard-xlpe-insulated-copper-cable-3x95sqmm/</guid>
				<description><![CDATA[applicazione: esso viene utilizzato per trasmettere e distribuire l&#039;alimentazione nel sistema di trasmissione e distribuzione di potenza 35kV o inferiore. &#232; generalmente applicato ai campi, tra cui potere, costruzione, miniere, metallurgia, industria petrolchimica e la comunicazione in completa sostituzione di carta a bagno d&#039;olio isolato cavo di alimentazione e in parziale sostituire di PVC isolato [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h5><strong><span style="font-size: 14.0px">applicazione:</span></strong></h5>
<h5><strong></strong><br /><span style="font-size: 12.0px">esso viene utilizzato per trasmettere e distribuire l&#039;alimentazione nel sistema di trasmissione e distribuzione di potenza 35kV o inferiore. &egrave; generalmente applicato ai campi, tra cui potere, costruzione, miniere, metallurgia, industria petrolchimica e la comunicazione in completa sostituzione di carta a bagno d&#039;olio isolato cavo di alimentazione e in parziale sostituire di PVC isolato alimentazione cavo.</span></h5>
<h5><span style="font-size: 14.0px">costruzione:</span></h5>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>conduttore: Rame (o Alluminio)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>isolamento: XLPE</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Filler: Non-igroscopico Polipropilene (PP)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Tape Binder: tessuto Non tessuto</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Rivestimento interno: PVC</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Metallic Armatura: Filo di Acciaio Zincato Armour (SWA)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Filo di Acciaio Non magnetico Armour (solo per single core)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Filo di alluminio Blindata (AWA, solo per single core)</strong></span></p>
<p style="line-height: 18.0px;font-family: arial , helvetica , sans-serif;color: #333333"><span style="font-family: arial , helvetica , sans-serif;color: #000000;font-size: 12.0px"><strong>Guaina esterna: PVC (o PE)</strong></span></p>
<h5><span style="font-size: 14.0px">standard:</span></h5>
<h5><span style="font-size: 12.0px">i prodotti sono principalmente conformi alla norma IEC 60502 standard, anche pu&ograve; essere prodotto secondo i requisiti OEM e altri standard, come ad esempio BS standard, DIN standard, ASTM standard, ecc</span><br /><span style="font-size: 12.0px">tensione grado &egrave; fino a 35kv, sezione area pu&ograve; essere fino a 400 sqmm (rame o alumimum conduttore). conduttore di lunga data temperatura di esercizio &egrave; di 90 &deg; C. In corto circuito, conduttore temperatura massima non deve essere superiore a 250 &deg; C</span></p>
</h5>
<h5><strong><span style="font-size: 14.0px">utilizzando caratteristiche:</span></strong></p>
<p><span style="font-size: 12.0px">tensione 1. Rated: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.</span><br /><span style="font-size: 12.0px">2. No. di core: Single-core, tre-core.</span><br /><span style="font-size: 12.0px">3. The massima consentita temperatura di funzionamento del conduttore per lavoro a lungo termine &egrave; di 90 &deg; C. In corto circuito (Max. A Lungo Termine &egrave; non pi&ugrave; di 5 secondi). la temperatura pi&ugrave; alta per il conduttore non &egrave; superiore a 250 &deg; C.</span><br /><span style="font-size: 12.0px">4. DC Resistenza del conduttore &egrave; conforme alle disposizioni di GB/T3956-1997.</span><br /><span style="font-size: 12.0px">5. L temperatura ambiente deve essere non inferiore a 0 &deg; C quando laici. altrimenti si deve essere preriscaldato.</span><br /><span style="font-size: 12.0px">6. Il cavo &egrave; posta senza limite di goccia orizzontale. il Min. raggio di Curvatura del cavo tripolare dovrebbe essere non pi&ugrave; piccolo di 12 volte di cavo esterno diametro.</span><br /><span style="font-size: 12.0px">7. Working Frequenza Tensione di Prova:.</span><br /><span style="font-size: 12.0px">per cavo con Uo di 3.6kV o inferiore: 2.5Uo + 2kV/5 min senza foratura.</span><br /><span style="font-size: 12.0px">per cavo con Uo di 3.6Kv ~ 18kV: 3.5Uo/5 min senza foratura.</span><br /><span style="font-size: 12.0px">per cavo con Uo di 21kV e 26 kV: 2.5Uo/30 min senza foratura.</span><br /><span style="font-size: 12.0px">8. Partial Prova di Scarica: Il volume di scarico dovrebbe essere non pi&ugrave; di 10 pz sotto 1.73Uo per il cavo.</span></h5>
<div style="overflow:auto"><table style="line-height: 18.0px;width: 652.0px;font-family: arial , helvetica , sans-serif;color: #333333;font-size: 12.0px" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr style="height: 29.25pt" align="middle">
<td style="margin: 0.0px;width: 3.0cm">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">tipo</span></p>
</td>
<td style="margin: 0.0px;width: 9.0cm">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">descrizione</span></p>
</td>
<td style="margin: 0.0px;width: 70.9pt">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">numero di core</span></p>
</td>
<td style="margin: 0.0px;width: 77.95pt">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">nominale sezione trasversale del conduttore</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA/PVC Cavo di Alimentazione</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1.5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA/PVC Cavo di Alimentazione</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV72</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/Non-magnetico SWA o AWA/PVC Cavo di Alimentazione</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1.5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV72</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/Non-magnetico SWA o AWA/PVC Cavo di Alimentazione</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJV33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA/PE Cavo di Alimentazione</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1.5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">YJLV33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA/PE Cavo di Alimentazione</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Z-YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA ritardante di Fiamma Cavo di Alimentazione</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1.5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">Z-YJLV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA ritardante di Fiamma Cavo di Alimentazione</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">WDZ-YJY33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA Fumo Basso Halogen Free o Pari A Zero Halogen (LSHF o LSZH) ritardante di Fiamma Cavo di alimentazione</span></p>
</td>
<td style="margin: 0.0px;height: 17.25pt" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px" rowspan="2">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1.5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">WDZ-YJLY33</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">AL/XLPE/SWA Fumo Basso Halogen Free o Pari A Zero Halogen (LSHF o LSZH) ritardante di Fiamma Cavo di alimentazione</span></p>
</td>
</tr>
<tr style="height: 17.25pt" align="middle">
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">N-YJV32</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">CU/XLPE/SWA resistente al Fuoco Cavo di Alimentazione</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1, 2, 3, 4, 3 + 1,</span></p>
<p align="center"><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">5, 4 + 1, 3 + 2</span></p>
</td>
<td style="margin: 0.0px">
<p><span style="line-height: 19.0px;font-family: comic sans ms , sans-serif;font-size: 10.0pt">1.5 ~ 1000mm<sup><span style="font-size: xx-small"><span style="font-size: xx-small">2</span></span></sup></span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<div style="overflow:auto"><table style="margin-left: auto;margin-right: auto" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr align="middle">
<td style="width: 122.4pt" colspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">tipo</span></p>
</td>
<td style="width: 108.0pt" rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">nome</span></p>
</td>
<td style="width: 195.7pt" rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">applicazione</span></p>
</td>
</tr>
<tr align="middle">
<td style="width: 59.4pt">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Cu</span></p>
<p align="center"><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">conducto</span></p>
</td>
<td style="width: 63.0pt">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">Al</span></p>
<p align="center"><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">conduttore</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">XLPE isolato, PVC o PE cavo elettrico inguainato</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">per la posa interna, tunnel, canale e la metropolitana. in grado di sopportare forza meccanica esterna durante posato.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJY</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">22</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium"><span style="font-size: large">22</span></span></sub></span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">XLPE isolato, nastro d&#039;acciaio corazzato, PVC o PE cavo elettrico inguainato</span></p>
</td>
<td rowspan="2">
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">per la posa interna, tunnel, canale e la metropolitana. in grado di sopportare esterno forza meccanica, ma in grado di sopportare grande forza di trazione.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">23</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLY<span style="font-size: medium"><span style="font-size: large"><sub>2</sub><sub>3</sub></span></span></span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">32</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium"><span style="font-size: large">32</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">XLPE isolato, belle filo di acciaio corazzato, PVC o PE cavo elettrico inguainato</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">per la posa in albero con grande differenza di livello. in grado di sopportare esterno forza meccanica, e moderata forza di trazione.</span></p>
</td>
</tr>
<tr align="middle">
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJV<sub><span style="font-size: medium"><span style="font-size: large">42</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">YJLV<sub><span style="font-size: medium"><span style="font-size: large">42</span></span></sub></span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">XLPE isolato, di spessore in acciaio corazzato, PVC o PE cavo elettrico inguainato</span></p>
</td>
<td>
<p><span style="font-family: comic sans ms , sans-serif;font-size: 18.0px">per la posa in albero con grande differenza di livello. in grado di sopportare esterno forza meccanica, e moderata forza di trazione.</span></p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://italian.baoliyy.com/iec-standard-xlpe-insulated-copper-cable-3x95sqmm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
