<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>NFA2X 4X70 + 2X35 &#8211; JYTOP Cable</title>
	<atom:link href="https://italian.baoliyy.com/tag/nfa2x-4x70-2x35/feed/" rel="self" type="application/rss+xml" />
	<link>https://italian.baoliyy.com</link>
	<description>Fabbricazione AAC / AAAC / ACSR CONDUCTOR, cavo XLPE, cavo in PVC, cavo ABC, cavo di alimentazione</description>
	<lastBuildDate>Fri, 06 Sep 2019 20:20:23 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>1kv transmission Overhead line NFA2X 4X70 + 2X35 aerial bundle cable</title>
		<link>https://italian.baoliyy.com/1kv-transmission-overhead-line-nfa2x-4x70-2x35-aerial-bundle-cable/</link>
				<comments>https://italian.baoliyy.com/1kv-transmission-overhead-line-nfa2x-4x70-2x35-aerial-bundle-cable/#respond</comments>
				<pubDate>Fri, 06 Sep 2019 20:20:23 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[zzhd]]></category>
		<category><![CDATA[1kv aerial bundle cable]]></category>
		<category><![CDATA[NFA2X 4X70 + 2X35]]></category>
		<category><![CDATA[NFA2X cable]]></category>

		<guid isPermaLink="false">https://italian.baoliyy.com/1kv-transmission-overhead-line-nfa2x-4x70-2x35-aerial-bundle-cable/</guid>
				<description><![CDATA[1kv trasmissione Luminosa linea NFA2X 4X70 + 2X35 bundle cavo dell&#039;antenna Descrizione del prodotto Overhead linea NFA2X Overhead linea NFA2X dati Tecnici: standard VDE 0274 (Z) materiale del conduttore alluminio conduttore di classe incagliato, classe 2 isolamento XLPE resistente AI RAGGI UV s&#236; cavo esterno temperatura consentita, fisso -20-+ 80 &#176; C applicazione: Per La [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<h2>1kv trasmissione Luminosa linea NFA2X 4X70 + 2X35 bundle cavo dell&#039;antenna</h2>
<div id="ali-anchor-AliPostDhMb-gg6jf" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-gg6jf" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Descrizione del prodotto</span></div>
<div style="padding: 10.0px 0">
<h1>Overhead linea NFA2X</h1>
<h3></h3>
<h4><span style="background-color: #ffff00">Overhead linea NFA2X dati Tecnici:</span></h4>
<div style="overflow:auto"><table style="margin: 0.0px 0.0px 1.5em;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;border-collapse: collapse;width: 609.0px;color: #76737b;font-family: helvetica , arial , sans-serif;font-style: normal;font-weight: normal;line-height: 27.0px;height: 189.0px;background: #ffffff">
<tbody>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 422.0px">standard</td>
<td style="width: 180.0px">VDE 0274 (Z)</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 422.0px">materiale del conduttore</td>
<td style="width: 180.0px">alluminio</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 422.0px">conduttore di classe</td>
<td style="width: 180.0px">incagliato, classe 2</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 422.0px">isolamento</td>
<td style="width: 180.0px">XLPE</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 422.0px">resistente AI RAGGI UV</td>
<td style="width: 180.0px">s&igrave;</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 422.0px">cavo esterno temperatura consentita, fisso</td>
<td style="width: 180.0px">-20-+ 80 &deg; C</td>
</tr>
</tbody>
</table></div>
<h4>applicazione: Per La distribuzione in testa, principalmente per la distribuzione pubblico con una tensione massima non superiore a 1.2 kV.</h4>
<h4><span style="background-color: #ffff00"></span></h4>
<h4><span style="background-color: #ffff00">Overhead linea NFA2X elenco di elementi:</span></h4>
<p><span style="font-size: 14.0px">i prodotti e le informazioni presentate qui sono per il tecnico di calcolo solo. essi sono soggetti al progresso tecnico e in nessun modo rappresentano la capacit&agrave; di spedizione. diametri esterni sono di circa.</span></p>
<div style="overflow:auto"><table style="margin: 0.0px 0.0px 1.5em;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;border-collapse: collapse;width: 611.0px;color: #76737b;font-family: helvetica , arial , sans-serif;font-style: normal;font-weight: normal;line-height: 27.0px;height: 533.0px;background: #ffffff">
<thead>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 14.0004px;vertical-align: baseline;background: transparent">
<td style="width: 157.0px">numero di articolo</td>
<td style="width: 295.0px">nome dell&#039;articolo</td>
<td style="width: 49.0px">Al<br />kg/km</td>
<td style="width: 43.0px">Cu<br />kg/km</td>
<td style="width: 51.0px">peso<br />kg/km</td>
</tr>
</thead>
<tbody>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 157.0px">NFA2X 04X25</td>
<td style="width: 295.0px">NFA2X 04X25 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">290.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">427.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 157.0px">NFA2X 01X16</td>
<td style="width: 295.0px">NFA2X 01X16 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">46.4</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">74.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 157.0px">NFA2X 01X25</td>
<td style="width: 295.0px">NFA2X 01X25 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">72.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">105.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 157.0px">NFA2X 01X35</td>
<td style="width: 295.0px">NFA2X 01X35 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">102.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">133.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 157.0px">NFA2X 01X50</td>
<td style="width: 295.0px">NFA2X 01X50 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">145.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">180.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 157.0px">NFA2X 01X70</td>
<td style="width: 295.0px">NFA2X 01X70 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">203.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">258.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 157.0px">NFA2X 04X16</td>
<td style="width: 295.0px">NFA2X 04X16 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">186.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">285.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 157.0px">NFA2X 04X35</td>
<td style="width: 295.0px">NFA2X 04X35 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">406.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">620.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 157.0px">NFA2X 04X50</td>
<td style="width: 295.0px">NFA2X 04X50 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">580.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">785.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 157.0px">NFA2X 04X70</td>
<td style="width: 295.0px">NFA2X 04X70 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">812.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">1032.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 157.0px">NFA2X 04X70 + 01X25</td>
<td style="width: 295.0px">NFA2X 04X70 RM + 01X25 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">885.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">1105.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 157.0px">NFA2X 04X70 + 01X35</td>
<td style="width: 295.0px">NFA2X 04X70 RM + 01X35 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">914.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">1150.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 157.0px">NFA2X 04X70 + 02X25</td>
<td style="width: 295.0px">NFA2X 04X70 RM + 02X25 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">956.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">1232.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 157.0px">NFA2X 04X70 + 02X35</td>
<td style="width: 295.0px">NFA2X 04X70 RM + 02X35 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">1016.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">1254.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: transparent">
<td style="width: 157.0px">NFA2X 04X95</td>
<td style="width: 295.0px">NFA2X 04X95 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">1102.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">1332.0</td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 18.0px;vertical-align: baseline;background: #e8e8e8">
<td style="width: 157.0px">NFA2X 04X95 + 01X35</td>
<td style="width: 295.0px">NFA2X 04X95 RM + 01X35 RM 0,6/1 kV SW</td>
<td style="width: 49.0px">1204.0</td>
<td style="width: 43.0px">&#8211;</td>
<td style="width: 51.0px">1468.0</td>
</tr>
</tbody>
</table></div>
<h4><span style="background-color: #ffff00">Overhead linea NFA2X Applicazione:</span></h4>
<p>per la distribuzione in testa, principalmente per la distribuzione pubblico con una tensione massima non superiore a 1.2 kV.</p>
<p>&nbsp;</p>
<h4>&nbsp;</h4>
<h4><span style="background-color: #ffff00">certificati, approvazioni:</span></h4>
<p><span style="font-size: 14.0px">CCC, ISO</span></p>
<p><span style="font-size: 14.0px">&nbsp;</span></p>
<p><span style="font-size: 14.0px">il cavo non contiene sostanze sulla portata lista.</span></p>
<p><span style="font-size: 14.0px">tutte le sostanze del cavo soddisfano i requisiti della direttiva RoHS.</span></p>
<p>&nbsp;</p>
<h4><span style="background-color: #ffff00">CODICE DOGANALE/CODICE di HS:</span><span style="font-size: 14.0px">85444921</span></h4>
<p><span style="font-size: 16.0px;background-color: #99ccff"><strong>maggiori informazioni e domande, pls contatto con Vivian Yuan. (Email: sale04 @ zzhongdacable.com.cn, WhatsApp/Wechat: 0086-15838290725, Skype: xinyuanyy)</strong></span></p>
</p>
</div>
</div>
<div>
<p>&nbsp;</p>
</p>
<p>&nbsp;</p>
<p><span style="font-size: 18.0px;background-color: #ffff99">tutte le immagini indicate qui solo a scopo di riferimento sono per le illustrazioni e di prodotto.</span></p>
</div>
<div id="ali-anchor-AliPostDhMb-gvshb" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-gvshb" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">imballaggio e Spedizione</span></div>
<div style="padding: 10.0px 0">
<p><span style="background-color: #ff99cc"><strong><span style="color: #000000;font-size: 16.0px;font-family: calibri , zapf dingbats">imballaggio:</span></strong></span></p>
<p>porta di legno in acciaio tamburo (fumigazione)<br />lunghezza del cavo in ogni tamburo: 500 m/1000 m o secondo effettiva lunghezza del cavo requisiti.</p>
<div style="overflow:auto"><table style="border-collapse: collapse;width: 581.0px;height: 181.0px;background-color: #ffffff" border="1">
<tbody>
<tr>
<td style="width: 380.0px"><span style="font-size: 14.0px"><strong>di piccola dimensione imballaggio in rullo</strong></span></td>
<td style="width: 270.0px"><span style="font-size: 14.0px"><strong>grande formato imballaggio in tamburo</strong></span></td>
</tr>
<tr>
<td style="width: 380.0px"></td>
<td style="width: 270.0px"></td>
</tr>
</tbody>
</table></div>
<p><strong><span style="color: #000000;font-size: 16.0px;font-family: calibri , zapf dingbats;background-color: #ff99cc">Drum dimensioni:</span></strong><br />secondo la lunghezza del cavo e dimensione del contenitore<br />* al fine di citare il prezzo esatto, gentilmente dirci la vostra lunghezza del cavo necessario quantit&agrave;. la pi&ugrave; grande quantit&agrave;, pi&ugrave; sconto beneficio pronti per voi!</p>
<p><span style="font-size: 16.0px;background-color: #ff99cc"><strong><span style="color: #000000;font-family: calibri , zapf dingbats">spese di spedizione:</span></strong></span><br />porto: Tianjin, Qingdao, o altre porte secondo il vostro requireents.</p>
<p><span style="background-color: #ff99cc"><strong><span style="color: #000000;font-size: 16.0px;font-family: calibri , zapf dingbats">trasporto di mare:</span></strong></span><br />FOB/C &amp; F/CIF citazione sono tutti disponibili.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-mvf5l" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-mvf5l" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Informazioni aziendali</span></div>
<div style="padding: 10.0px 0">
<p align="center" style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;font-size: 12.0px;font-style: normal;font-weight: normal;line-height: 18.0px;vertical-align: baseline;color: #333333;text-align: left;background-color: #ffffff"><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: calibri , zapf dingbats;font-size: 18.0px;font-style: inherit;line-height: 18.0px;vertical-align: baseline;color: #ffffff;background-color: #3366ff"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: normal;line-height: normal;vertical-align: baseline">Profilo aziendale</span></span></strong></p>
<p>Hongda cavo Co., Ltd. &egrave; uno dei pi&ugrave; produttore professionale cable &amp; wire sotto moderno sistema aziendale in Cina, che &egrave; stata fondata nel 1988, integrare la ricerca scientifica, sviluppo, produzione e vendita. l&#039;azienda produce principalmente 1-35 kV cavo di alimentazione, 35mm cavo in cavi elettrici, AAC, AAAC, ACSR.</p>
<p>i nostri vantaggi</p>
<p>1. With pi&ugrave; di 17 anni di esperienza di fabbricazione, i nostri prodotti sono rigorosamente in conformit&agrave; con ISO, CE, UL e BV;</p>
<p>2. Good costo-sistema di controllo, con altamente competitivi;</p>
<p>3. Strong e Professionale team R &amp; D per soddisfare le vostre esigenze specifiche;</p>
<p>consegna 4. Fast e prodotti affidabili sono sempre il motivo per cui si sceglie di noi.</p>
</p>
<p>&nbsp;</p>
</div>
</div>
<div id="ali-anchor-AliPostDhMb-0os3u" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-0os3u" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">Informazioni di contatto</span></div>
<div style="padding: 10.0px 0">
<p><strong><span style="color: #0000ff;font-size: 16.0px">informazioni di contatto</span></strong></p>
<p><span style="color: #0000ff;font-size: 16.0px">&nbsp;</span></p>
<p><span style="color: #0000ff;font-size: 16.0px">eventuali esigenze o domanda, non esitate a contattarci, saremo pi&ugrave; piacere di un servizio.</span></p>
<p><span style="color: #0000ff;font-size: 16.0px">&nbsp;</span></p>
<p><span style="color: #0000ff;font-size: 16.0px">siamo lieti della vostra inchiesta e piacevole cooperaton.</span></p>
<p>&nbsp;</p>
</p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://italian.baoliyy.com/1kv-transmission-overhead-line-nfa2x-4x70-2x35-aerial-bundle-cable/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
